Re: 1.95 ratio


[ Follow Ups ] [ Post Followup ] [ Meshing with Gears Discussion Forum ] [ FAQ ]

Posted by tom on October 05, 2014 at 13:30:53:

In Reply to: Re: 1.95 ratio posted by Ron V on October 03, 2014 at 16:19:41:

module 3,175 is too small !!
You need to use module 3,25 a.p.20
Working pressure angle 2816'49'
Helix angle on pitch diameter 30
z19 z37
Outside diam. 81,20 150,63
Distance centres correct 110
Base diameter 65,73 128,0
Number teeth on measurement
5 8
Chordal measurement
45,95 76,61


Dim. the ruller 86,57 156,41
Ruller diameter 7 7